The hardware

Connected inhalers, two ways.

Respiro connects inhaled therapy through the hardware route that fits the programme: RS01X, the fully integrated connected evolution of the widely used RS01 capsule DPI, or smart inhaler sensors for inhalers already selected, launched or familiar to patients. Both capture dose and inhalation-technique data for the same Respiro platform.

Integrated or add-on Dose + inhalation technique Same app, cloud & APIs Plastiape manufacturing partner
Two device families

Choose the route that fits the therapy.

RS01X carries the RS01 device heritage forward as a fully integrated connected inhaler. Add-on smart inhaler sensors bring the same Respiro capture layer to inhalers a programme has already committed to.

Industrial-design concept sketch of the RS01X connected inhaler
Integrated · flagship

RS01X connected inhaler

The connected evolution of Plastiape's RS01 capsule DPI: Respiro sensing is fully integrated in the familiar capsule-inhaler format.

  • Sensing integrated into the inhaler
  • Co-developed with Plastiape, the device manufacturing and supply partner
  • Captures peak inspiratory flow, duration and volume
Explore RS01X
Industrial-design concept sketch of an RS01 inhaler with a clip-on Respiro add-on sensor
Retrofit

Add-on sensors

Clip-on modules, co-developed with Plastiape, that bring Respiro sensing to the inhalers patients already hold, without changing the core delivery device.

  • Fits common formats: capsule DPI, pMDI and multi-dose DPI
  • Captures dose timing plus format-specific technique signals
  • Respiro app, data platform, dashboards and APIs
See the range
Same platform underneath

Two hardware routes, one data platform.

Partner

Hardware programmes are co-developed with Plastiape, the manufacturing and supply partner.

Capture

Dose events and device-specific technique parameters are captured at the inhaler.

Sync

Inhaler-use records flow to the Respiro app and data platform.

Use

The same signal powers patient feedback, clinical workflows and partner evidence.

The add-on range

Add-on options for common inhaler formats.

Explore add-on options for different inhaler formats. The records and technique details available depend on the selected sensor model.

Concept sketch of an RS01 capsule inhaler with a clip-on Respiro add-on sensor

RS01 capsule

Single-dose capsule DPI

Built for the RS01 capsule inhaler, when a programme wants connected sensing without the integrated RS01X.

PIFDurationVolumeOrientation
Concept sketch of a pressurised metered-dose inhaler with a clip-on Respiro add-on sensor

Metered-dose inhaler

Pressurised metered-dose inhaler

For selected pressurised metered-dose inhalers, with the coordination and shake information available for the selected model.

PIFDurationVolumeOrientationCoordinationShake
Concept sketch of an Ellipta multi-dose dry-powder inhaler with a clip-on Respiro add-on sensor

Ellipta

Multi-dose DPI

Built for the Ellipta multi-dose DPI, with a module that keeps the patient's handling familiar.

PIFDurationVolumeOrientation

We work with Plastiape on connected device programmes, bringing together inhaler expertise and Respiro sensing. Discuss the design, manufacturing and supply route for the device you need.

Don't see your inhaler? Talk to us about a custom add-on

What the sensors read

Every inhalation, measured.

Each device captures the technique parameters that matter for its inhaler type: the raw signal Respiro turns into records of doses taken, inhalation-technique information and real-world evidence.

Time Flow Peak Inspiratory Flow 62 L/min Inhaled Volume 1.1 L 1.7 s Inhalation Duration

Only 31% of patients use their inhaler correctly — the rest make technique errors that stay invisible until something measures them.Sanchis et al., systematic review of inhaler technique, Chest 2016 — 144 studies, 54,354 patients.

A single inhalation, described against ranges from published studies for this type of inhaler — a basis for technique conversations, not a measure of lung function.

Validated

Measurements you can trust.

RS01X validation puts Respiro's on-device sensing against a laboratory reference, for inhalation duration, volume and peak inspiratory flow in the study configuration.

Read the RS01X validation
ICC > 0.95 Agreement for the three measures studied.
97 participants Asthma, COPD and healthy participants included.
Lab reference On-device sensing compared against laboratory measurement.
Where they fit

Hardware is one layer of the platform.

A connected inhaler is never just a device. It's the capture layer of Respiro, and the data it produces is what becomes evidence.

Make your inhaled therapy connected.

Explore RS01X or an add-on sensor as the starting point for your connected inhaler programme.